5-5
Parameters Description Setting range Unit
Take effect
method
Related
chapter
CN011
First stage CW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-2-5
TN101.0
Torque command
acceleration/deceleration method
0 ~ 3 --
After Servo
OFF
5-2-3
TN101.1 Torque command selection 0 ~ 1 --
After Servo
OFF
5-2-1
TN101.2 Speed limit value switching function 0 ~ 1 --
After Servo
OFF
5-2-6
TN102
Torque command straight line
acceleration/deceleration constant
1 ~ 50000 ms
After Servo
OFF
5-2-3
TN103 Analog torque command proportioner 0 ~ 600 %/10V
Take effect
after setting
5-2-1
TN104
Analog torque command offset
adjustment
-2500 ~ 2500 mV
Take effect
after setting
5-2-1
TN105 Internal speed limit 1
0 ~ 1.5* rated
rotation speed
rpm
Take effect
after setting
5-2-6
TN106 Internal speed limit 2
0 ~ 1.5* rated
rotation speed
rpm
Take effect
after setting
5-2-6
TN107 Internal speed limit 3
0 ~ 1.5* rated
rotation speed
rpm
Take effect
after setting
5-2-6
TN109 Analog speed limit proportioner 100 ~ 10000 rpm
Take effect
after setting
5-2-6
TN110
Torque command one-time smooth
acceleration/deceleration constant
1 ~ 10000 ms
After Servo
OFF
5-2-3
TN113 Digital torque command value -3000 ~ 3000 0.1%
After Servo
OFF
5-2-2
TN114 Internal forward speed limit
0 ~ 1.5* rated
rotation speed
rpm
Take effect
after setting
5-2-6
TN115 Internal reverse speed limit
0 ~ 1.5* rated
rotation speed
rpm
Take effect
after setting
5-2-6
TN116 Analog torque command filter 0 ~ 5000 Hz
Take effect
after setting
5-2-1
TN117
Torque command straight line
deceleration constant
1 ~ 50000 ms
After Servo
OFF
5-2-3
TN118
Signal delay time for reaching INT
torque
0~5000 ms
Take effect
after setting
5-2-1
SN217
Zero analog speed command offset
adjustment
-2500 ~ 2500 mV
Take effect
after setting
5-2-6
SN226 Analog speed command filter 0 ~ 2500 Hz
Take effect
after setting
5-2-6
Note: Servo gain adjustment related parameters were not listed above; please refer to “6 Servo Gain