5-12
Tn117 Torque command straight line deceleration constant
Initial Value Unit Setting Range Effective RS-485 Address
1 ms 1 ~ 50000 After Servo OFF 0111H
Setting description: The definition of torque command straight line deceleration constant is the time
for the torque command to decrease in a straight line from the rated torque to zero.
Torque
command
Time (ms)
Tn102
Rated torque
command
Current
torque
command
Tn117
Setting example:
(1) To reach 50% of the rated torque output in 10ms
20(ms)
50%
100%
10(ms)Tn102
(2) To reach 75% of the rated torque output in 10ms
13(ms)
75%
100%
10(ms)Tn102