5-17
Tn114 Internal Forward Rotation Speed Limit
Initial Value Unit Setting Range Effective RS-485 Address
100 rpm 0 ~ 1.5*Rated Speed Effective after Set 010EH
Setting Description: Set Tn101.2=1, set the Forward Speed Limit value in Torque Mode with this
parameter.
Tn115 Internal Reverse Rotation Speed Limit
Initial Value Unit Setting Range Effective RS-485 Address
-100 rpm
-1.5*rated rotational
speed ~ 0
Effective after Set 010FH
Setting Description: Set Tn101.2=1, set the Reverse Speed Limit value in Torque Mode with this
parameter.
Following is External Analog Speed Limit Command Wiring Diagram:
Cooperate with analog speed command filter Sn226 to adjust the filtering effect of analog speed
limit. Adjust the slope of Voltage Command relative to Torque Command in coordination with Analog
Torque Command Proportioner Tn109, and Sn217 to correct Analog torque command voltage offset.
Tn109 Analog speed limit proportioner JSDG2S-E does not have this function
Initial Value Unit Setting Range Effective RS-485 Address
Rated Speed rpm 100 ~ 10000 Effective after Set 0109H
Setting Description: Used to adjust the slope of Voltage Command relative to the Speed Limit