EasyManua.ls Logo

TECO JSDG2S Series - Page 156

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-31
(3) S-type Speed Command Acceleration / Deceleration:
To use this function, Sn205.0=3 must be set to activate S-type Speed Command Acceleration /
Deceleration Function.
Sn208 S-type Speed Command Acceleration / Deceleration Time Setting (t
S
)
Initial Value Unit Setting Range Effective RS-485 Address
1 ms 1 ~ 1000 Effective after Set 0208H
Setting Description: Set Sn205.0=3 to activate S-type Speed Command Acceleration / Deceleration
Function. During Acceleration / Deceleration, due to the severe Acceleration /
Deceleration Changes when activating Stop that resulted in machine oscillation,
adding S-type Acceleration / Deceleration to Speed Command can achieve the
function of smooth operations.
Speed Command (rpm)
Time (ms)
ts ts
ta
ts
ts
td
ts=Sn208
ta=Sn209
td=Sn210
Sn209 S-type Speed Command Acceleration Time Setting (t
a
)
Initial Value Unit Setting Range Effective RS-485 Address
200 ms 1 ~ 20000 Effective after Set 0209H
Setting Description: Please refer to Sn208 Description
Sn210 S-type Speed Command Deceleration Time Setting (t
b
)
Initial Value Unit Setting Range Effective RS-485 Address
200 ms 1 ~ 20000 Effective after Set 020AH
Setting Description: Please refer to Sn208 Description
Attention! Setting Rules: ,
2
a
s
t
t
s
d
t
t
2

Table of Contents