5-48
This device provides a pulse wave response filter to adjust the pulse wave command response. The
larger the value, the faster the response. The recommended value is 2 times the position loop gain.
Pn332.3 Pulse response filter flag
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Effective after Set 0329H
Setting Description:
Setting Description
0 Disable pulse response filter.
1
Enable pulse response filter, and operate
according to the setting value of Pn356.
Pn356 Pulse Response Filter
Initial Value Unit Setting Range Effective RS-485 Address
40 Hz 1 ~ 1000 Effective after Set 0345H
Setting Description: Adjust the pulse command response, the larger the value, the faster the response
The recommended value is 2 times the position loop gain
RS-485 Pi Pe Pt S T
0329H O -- O -- --