Pn301.1 Position Pulse Command Logic Selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power Re-set 0301H
Setting Description:
Setting Description
0 Positive Logic
1 Negative Logic
Pn301.2 Drive inhibits Command Receiving Selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power Re-set 0301H
Setting Description:
Setting Description
0
After the Drive Prohibition occurs, continue
recording the Position Command Input Quantity.
1
After the Drive Prohibition occurs, ignore Position
Command Input Quantity.
Pn301.3 Position Pulse Command Filter Width Selection
Initial Value Unit Setting Range Effective RS-485 Address
1 -- 0 ~ 7 Power Re-set 0301H
Setting Description:
Setting Description Setting Description
0 4500KHz 4 370KHz
1 2500KHz 5 190KHz
2 1200KHz 6 90KHz
3 750KHz 7 40KHz