EasyManua.ls Logo

TECO JSDG2S Series - Page 181

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-56
Electronic gear ratio setting method (1) – Directly set the number of pulse command for a
single rotation
1. Understand the overall system specifications
Obtain the System Specification first in order to determine the Electronic Gear Ratio, such as:
Reduction Ratio, Gear Ratio, the quantity of movement for one revolution of the Load Axis, and the
diameter of Roller. Please refer to "1-1-2 Confirmation of Servo Motor Model".
2. Define One Pulse Command Moving Distance
Define the distance that the Transmission Device will move when the Supervisory Controller
issues a Pulse Command. For example: when one pulse commands to move 1um
3. Calculate Single Rotation Pulse Command
If the deceleration ratio between the Motor and the Load Shaft is
m
n
(m refers to the number of
Motor rotations and n the number of Load Shaft rotations), single-rotation Pulse Command will be
calculated according to the following formula.
SingleRotationPulseCommand
Thedistanceoftheloadmovement
byonerevolutionoftheLoadShaft
OnePulseCommandMovingDistance

Directly input the number of Single Rotation Pulse Commands to Pn354 Single Rotation Pulse
Command Function
Pn354 Single Rotation Pulse Command Function
Initial Value Unit Setting Range Effective RS-485 Address
0 pulse
Determined by the Encoder
0 ~ 10000: 2500ppr encoder
0 ~ 32768: 15bit encoder
0 ~ 131072: 17bit encoder
0 ~ 8388608: 23bit encoder
Note: 0 ~ 63 means not use
Power Re-set 0342H/0343H
Setting Description:
External Pulse mode: The pulse command required by one motor revolution. When set as a value
64, Single pulse command function activates and Pn302~Pn306 E-Cam ratio
function becomes invalid.
Interal Position mode: The magnification of the internal position command movement. When set as a
value 64, Internal position command magnification activates and
Pn302~Pn306 E-Cam ratio function becomes invalid.