EasyManua.ls Logo

TECO JSDG2S Series - Page 282

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-157
EC906 Start angle of E-Cam
Initial Value Unit Setting Range Effective RS-485 Address
0 0.01 degree -9000 ~ 9000 Effective after Confirmed 0806H
Setting Description: When the flying shear function is selected, the synchronized angle refers to the
angle the auxiliary axle travels when the main axle and auxiliary axle shares the
same speed (Definition: 1 revolution = 360-degree).The definition is “the start
angle of the first tool touching the cutting point” - “the defined point of start
angle”. The defined point of start angle is 180-
/
and the setting range
is


~


. For example: if ECA04=3, then the defined point is
120-degree and the angle difference between the first tool and defined point is
the setting value of ECA06.
EC907 Encoder resolution of E-Cam main axle
Initial Value Unit Setting Range Effective RS-485 Address
2500 ppr 1 ~ 32768
Effective after Confirmed
0807H
Setting Description: Main axle (feeding axle) encoder resolution.The resolution of main/auxiliary
motor encoder. For incremental type, then input motor resolution; for
communication type, input resolution per rotation/4. For example, for
communication type 17bit motor, then input 131072/4=32768 in this parameter.
EC908 Encoder resolution of E-Cam auxiliary axle
Initial Value Unit Setting Range Effective RS-485 Address
2500 ppr 1 ~ 32768
Effective after Confirmed
0808H
Setting Description: Auxiliary axle (cutter axle) encoder resolution.
CUT point is the cutter position
120-degree between each tool
ECA06 Start angle
120 degree=Definition point
180 degree=Cutting point
0 degree
CUT point
CUT point

Table of Contents

Related product manuals