EasyManua.ls Logo

TECO JSDG2S Series - Page 290

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-165
Pn351 Gantry synchronization controller gain value
Initial Value Unit Setting Range Effective RS-485 Address
10 rad/s 0 ~ 10000
Effective after Confirmed
033EH
Setting Description: Gantry synchronization controller gain value. The larger the value, the smaller
the synchronization error can be suppressed.
Pn352 Gantry synchronization maximum error tolerance
Initial Value Unit Setting Range Effective RS-485 Address
0 pulse 0 ~ 268435456
Effective after Confirmed
033FH/0340H
Setting Description: Maximum error between 2 axes tolerated by the machine
Pn348 Corresponded resolution of Full-closed loop Encoder one circle
Initial Value Unit Setting Range Effective RS-485 Address
1250 ppr 256 ~ 1048576 Power Re-set 033AH/033BH
Setting Description: The number of pulses corresponding to the external optical ruler when the motor
rotates one circle (Encoder resolution of the full-closed loop CN8 connection)
Hardware connection:
Name two sets of encoder as A and B. Connect the linear scale signal of A to CN8 of driver B
and the linear scale of B to CN8 of driver A. This can also be achieved by dividing if there is
no linear scale.
Need to make sure the position command is given to driver A & B simultaneously. For
example, short-circuit PP & PN of two machines respectively and connect to the signal
generator.

Table of Contents