5-172
If used with analog over-temperature signal, please connect it to the SIC pin or TIC pin of the servo
drivers CN1, and set the servo parameters Cn009.3 (analog voltage over-temperature protection
function setting) and Cn086 (analog voltage over-temperature protection function). When exceeded
the value set, AL.052 external sensor over-temperature will be generated.
CN1-26
CN1-29
Driver
SIC
AG
Temperature signal
10V)
CN1-27
TIC
or
Cn009.3 Analog voltage over-temperature protection function settings
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 2 Take effect after setting 000AH
Setting description:
Setting Description
0 Not used
1 The TIC function switch is an over-temperature protection signal
2 The SIC function switch is an over-temperature protection signal
Cn086 Analog voltage over-temperature protection function
Initial Value Unit Setting Range Effective RS-485 Address
200 0.01V 0 ~ 1000 Take effect after setting 0059H
Setting description: According to the setting of Cn009.3, compare the setting value of Cn086, if the
value exceeds, the AL.052 alarm will be triggered.