6-16
Cn060 OFFLine-tuning operation command lap setting
Initial Value Unit Setting Range Effective RS-485 Address
30 0.1rev 5 ~ 2000
Effective after
confirmation
003FH
Setting description: Setting it as 30 means that the tuning process command will be within 3 laps
Cn061 OFFLine-tuning operation maximum rotation speed
Initial Value Unit Setting Range Effective RS-485 Address
2/3* rated
rotation speed
rpm 300 ~ 2/3* rated rotation speed
Effective after
confirmation
0040H
Setting description: The maximum operation rotation speed of OFFLine_Tuning