6-19
(2) Use PC-Link to run automatic mechanical resonance suppression enablement selection parameter
to look for suppression frequency
1. Click “Tuning (T)” on the tool bar and select “Online Notch (N)”
2. Set Cn063.0 (automatic mechanical suppression enabling selection)=1~5 and select “write in” key
to enable automatic detection of mechanical vibration frequency.
3. When finding the resonance point, it will be displayed in Notch Filter setting value column
(Cn013, Cn066, Cn069, Cn072 & Cn075) and automatically return Cn063 (Disable Automatic
Detection of Mechanical Vibration Frequency) to 0.
4. If the resonance point cannot be found, Cn063 (Disable Automatic Detection of Mechanical
Vibration Frequency) will return to 0 automatically after finding the resonance frequency for a
period of time.