EasyManua.ls Logo

TECO JSDG2S Series - 7-3 Parameter Function Detail description

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-8
Position Control Parameter (Pn3□□)
Parameter Code Name and Function Unit RS485 Index
Pn301.0 Position Pulse Command pattern Selection
- 0301H -
Pn301.1 Position Pulse Command Logic Selection
Pn301.2 Drive Prohibited Command Receiving Selection
Pn301.3 Position Pulse Command Filter Width Selection
-- Pn302 Electronic Gear Ratio Numerator 1 - 0302H/0303H -
-- Pn303 Electronic Gear Ratio Numerator 2 - 0304H/0305H -
-- Pn304 Electronic Gear Ratio Numerator 3 - 0306H/0307H -
-- Pn305 Electronic Gear Ratio Numerator 4 - 0308H/0309H -
Pn306 Electronic Gear Ratio Denominator - 030AH/030BH -
-- Pn307 Positioning Completion Determined Value pulse 030CH/030DH 2307H
-- Pn308 Positive Maximum Position Error Determined Value 0.001rev 030EH 2308H
-- Pn309 Negative Maximum Position Error Determined Value 0.001rev 030FH 230AH
-- Pn310 Position Loop Gain 1 rad/s 0310H 230BH
-- Pn311 Position Loop Gain 2 rad/s 0311H 230CH
-- Pn312 Position Loop Feed Forward Gain % 0312H 230DH
Pn313
Internal / External Position Command One time
Smoothing Acceleration / Deceleration Time
Constant
ms 0313H 230EH
Pn314.0
Position Command Direction Definition (from the
Motor Load End)
- 0314H -
-- Pn315.0 Pulse Error Clearing Mode
- 0315H -
-- Pn315.1 Origin return offset mode setting
-- Pn315.2
Turret & Tool Magazine Zero Return Method
Selection
Pn316.0 Internal Position Command Mode
- 0316H 2310H
Pn316.1
Internal Position Command Hold (PHOLD)
Procedure Selection
Pn316.2 Encoder Signal Dividing Output Phase Sequence
Pn316.3
Encoder Signal Dividing Output Frequency
Elimination
-- Pn317.0
After activated Return to Origin, the Origin Search
Direction and Select Origin Reference Point Setting
- 0317H -
-- Pn317.1
After Found Origin Reference Point, the Moving
Method of Search Mechanical Origin Setting
-- Pn317.2 Return to Origin Activation Mode Setting
-- Pn317.3 Stop Mode after Found Mechanical Origin Setting
-- Pn318 Return to Origin First Stage High Speed rpm 0318H -
-- Pn319 Return to Origin Second Stage Low Speed rpm 0319H -
-- Pn320 Return to Origin Offset Number of Revolutions rev 031AH -
-- Pn321 Return to Origin Offset Number of Pulses pulse 031BH/031CH -
-- Pn322 Internal Position Command S-type Acceleration / 0.4ms 031DH -

Table of Contents

Related product manuals