EasyManua.ls Logo

TECO JSDG2S Series - Page 420

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-58
Tn102 Torque Command Linear Acceleration / Deceleration Constant5-2-3
Initial Value Unit Setting Range Effective Cn029 Reset
1 ms 1 ~ 50000 --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0102H 2102H 2102H - - - - O
Setting Description: The Torque Command Linear Acceleration/Deceleration Constant is defined as the time for the
Torque Command to rise from zero linearly to the Rated Torque.
Tn103 Analog torque command proportioner
JSDG2S-E(L) does not have this
function
5-2-1
Initial Value Unit Setting Range Effective Cn029 Reset
300 %/10V 0 ~ 600 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0103H - - - - - - O
Setting Description: Used to adjust the slope of the Voltage Command relative to the Torque Command.
Setting Example:
(1) If Tn103 is set to 300, indicating the Input Voltage 10V corresponds to 300% rated Torque Command; if the Input
Voltage is
5V at this time, the it corresponds to 150% rated torque command.
(2) If Tn103 is set to 200, indicating the Input Voltage 10V corresponds to 200% rated Torque Command; if the Input
Voltage is 5V at this time, then it corresponds to 100% rated Torque Command.