7-60
Setting Description: In Torque Control, the Digital Input Contact SPD1, SPD2 can be used to switch 3 sets of Internal
Speed Limit. When using Internal Speed Limit 2, the DigitalInput Contact SPD1, SPD2 states are as
the following combination:
Digital Input Contact SPD2 Digital Input Contact SPD1
1 0
Tn107 Internal Speed Limit 3
5-2-6
Initial Value Unit Setting Range Effective Cn029 Reset
300 rpm 0 ~ 1.5*Rated Speed -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0107H - - -- -- -- -- O
Setting Description: In Torque Control, the Digital Input Contact SPD1, SPD2 can be used to switch 3 sets of Internal
Speed Limit. When using Internal Speed Limit 3, the DigitalInput Contact SPD1, SPD2 states are as
the following combination:
Digital Input Contact SPD2 Digital Input Contact SPD1
1 1
Tn108 Torque Reached Determined Value
5-2-7
Initial Value Unit Setting Range Effective Cn029 Reset
0 % 0 ~ 300 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0108H 2108H 2108H O O O O O
Setting Description: When the Forward or Reverse Torque exceeds the set level, the Digital Output Contact INT operates.
Tn109 Analog speed limit proportioner
JSDG2S-E(L) does not have this function
5-2-6
Initial Value Unit Setting Range Effective Cn029 Reset
Rated Speed rpm 100 ~ 10000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0109H - - - - - - O
Setting Description: Used to adjust the slope of the Voltage Command relative to the Speed Limit.
Note): This parameter is the same as Sn216, with different functions under different modes.