7-94
Pn356 Pulse Response Filter
Initial Value Unit Setting Range Effective Cn029 Reset
40 Hz 1 ~ 1000
--
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0345H -- -- -- O -- -- --
Setting Description: Adjust the pulse command response, the larger the value, the faster the response.
The recommended value is 2 times the position loop gain.
Pn357 Positive software limit
Initial Value Unit Setting Range Effective Cn029 Reset
0 Unit/PLS -536870911~536870911
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0346H/0347H 2339H 2339H O O O O O
Setting Description: When the motor runs to the limit value, it will lock to 0 revolutions and output DO SLIT, and the
panel will display NSL. If the setting value Pn357 <Pn358, AL.064 (Software limit setting error) will
be triggered.
Pn358 Negative software limit
Initial Value Unit Setting Range Effective Cn029 Reset
0 Unit/PLS -536870911~536870911
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0348H/0349H 233AH 233AH O O O O O
Setting Description: When the motor runs to the limit value, it will lock to 0 revolutions and output DO SLIT, and the
panel will display NSL. If the setting value Pn357 <Pn358, AL.064 (Software limit setting error) will
be triggered.
Pn359 Backlash compensation parameters in CW direction of Turret & Tool
magazine
Initial Value Unit Setting Range Effective Cn029 Reset
0 pulse -8388607~ 8388607
--
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
034AH/034BH -- -- -- -- O -- --
Setting Description: Set the backlash compensation value.