7-113
tn831.0 OFFLine-tuning inertia ratio selection
Initial value Unit Setting range Effective Cn029 reset
1 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
131FH 2D1FH 2D1FH O O O O --
Setting description:
Setting Description
0 Do not tune the load inertia ratio automatically
1 Tune the load inertia ratio automatically
tn832.0 Program Jog stoke running flag4-4
Initial value Unit Setting range Effective Cn029 reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1320H 2D20H 2D20H O O O
--
--
Setting description:
Setting Description
0 Disable stroke operation
1 Enable stroke operation
tn832.1 Program Jog execution direction selection4-4
Initial value Unit Setting range Effective Cn029 reset
0 -- 0 ~ 3 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1320H 2D20H 2D20H O O O -- --
Setting description:
Setting Description
0 Forward=>Reverse
1 Reverse=>Forward
2 Forward=>Forward
3 Reverse=>Reverse