7-128
EC920 Maximum return speed of E-Cam rotary cut
5-6-15
Initial Value Unit Setting Range Effective Cn029 Reset
0 rpm 0 ~ 3000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
081CH -- -- O -- -- -- --
Setting Description: Set the maximum return speed of rotary cut. The program will run internal calculation by itself when
the setting is 0.
EC921 Acceleration/Deceleration time of E-Cam rotary cut
5-6-15
Initial Value Unit Setting Range Effective Cn029 Reset
0 ms 0 ~ 50000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
081DH -- -- O -- -- -- --
Setting Description: Set the acceleration/deceleration time of rotary cut. The program will run internal calculation by itself
when the setting is 0.
EC922 Enable E-Cam parameter change write-in
5-6-15
Initial Value Unit Setting Range Effective Cn029 Reset
0 - 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
081EH -- -- O -- -- -- --
Setting Description: Set this parameter as 1 when changing the parameter to enable parameter change
EC923 E-Cam parameter fine-tune factor
5-6-15
Initial Value Unit Setting Range Effective Cn029 Reset
10000 0.01 0 ~ 65535 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
081FH -- -- O -- -- -- --
Setting Description: Fine-tune cutting length to correct machine error