EasyManua.ls Logo

TECO JSDG2S Series - Page 99

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-13
Parameter
Code
Display Content Unit Description
RS-485
Address
Index
Un-72
Turret monitor
parameter 2
0653H
Un-73
Turret monitor
parameter 3
0654H
Un-74
Turret monitor
parameter 4
0655H
Un-75
Turret monitor
parameter 5
0656H
Un-76
Turret monitor
parameter 6
0657H
Un-84
Encoder category
0: Incremental type
1: Absolute value type
065FH 2854H
Un-88
ServoOn total time hour ServoOn total time 0663H 2858H
Un-89
PowerOn total time hour PowerOn total time 0664H 2859H
Un-90
Effective load rate % Effective load rate
0665H 285AH
Un-91
Color mark distance 0.1mm
The travel distance of the spindle corresponding
to two DI signals
0666H 285BH
Un-92
Cut point error pulse
The error value of the spindle when the tool
reaches the cut point
0667H 285CH
Un-93
Slave axis state -
Un-93.0
0: Initialization completed
1: From the axis to the actual zero position, and
stop
2: The slave axis starts to run, but it has not yet
reached the synchronization area
3: The slave axis is in the synchronization area
4: The slave axis has passed the synchronization
area, but has not reached the logic zero position
Un-93.1
(DI 0x25 E-STOPIN input)
0: Allow slave axis running
1: The slave axis is not allowed to start a new
operating cycle
0668H 285DH
Un-94
Slave axis angle 0.01deg Slave axis angle
0669H
066AH
285EH
Un-95
Lost bids times time Lost bid times
066BH 285FH
Un-96
System unit quantity
position feedback
unit/PLS System unit volume position feedback
066CH
066DH
2860H
Un-97
System unit quantity
position command
unit/PLS System unit volume position command
066EH
066FH
2861H
Note 1: JSDG2S-E(L) does not have this function