EasyManuals Logo

Tektronix 2230 Operator's Manual

Tektronix 2230
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
Commands
2230
DELAy?
2230
DELAy? VALue
2230
DELAy? UNlts
ALL
HORizontal?
ALL
HORizontal? ASEdiv
2230
HORizontal? BSEdiv
ALL
HORizontal? EXTclk
--
ALL
HORizontal? HMAg
2230
HORizontal? MODe
Options and
Accessories-2230
Operators
Table 7-23
Horizontal Commands
Description
Returns the present horizontal delay settings
as:
DELA
VAL:<NR3>,UNl:<S
or
DIV>.
Returns
an
<NR3>
value that represents the present delay value
in
the units
returned
by
the UNlts query
as:
DELA
VAL:<NR3>.
Returns a string of either S or
DIV
that corresponds to the DELAy? VALue units
as: DELA
UNl:<S
or
DIV>.
The
units
are
DIV
when the SEC/DIV knob
is
set to
EXT
CLK.
Returns
all
present horizontal settings
as
appropriate for the type of instrument.
Returns
an
<NR3>
value
that represents the present A SEC/DIV setting
in
the
form:
HOR
ASE:<NR3>.
The
value returned
is
zero
when
the SEC/DIV knob
is
set to
EXT
CLK.
Returns
an
<NR3>
value that represents the present B SEC/DIV setting
in
the
form:
HOR
BSE:<NR3>.
Returns the state of the external clock as:
HOR
EXT:<ON or
OFF>.
Returns the state of the
X10
magnifier as:
HOR
HMA:<ON
or
OFF>.
Returns the present horizontal mode setting as:
HOR
MOD:
<ASW,
AIN,
or
SSW>.
7-27

Table of Contents

Other manuals for Tektronix 2230

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2230 and is the answer not in the manual?

Tektronix 2230 Specifications

General IconGeneral
BrandTektronix
Model2230
CategoryTest Equipment
LanguageEnglish

Related product manuals