EasyManua.ls Logo

tell Adapter2 - Page 42

tell Adapter2
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
CID reporting to CMS over IP:
You can configure up to 4 CMS servers or receivers with the following parameters:
Name: CMS server or receiver name. The name entered in this section is used for identification
of the server/receiver within the program, and the program will also use this name when
configuring notification templates.
IP address/domain name: CMS server or receiver IP address or domain name. When a SIM card
with a private APN is used, and the given server or receiver is not in the same APN, it is necessary
to enable access of the server/receiver IP address in the given APN.
Port: CMS server or receiver communication port number.
Default port numbers:
TELLMon protocol (TCP): 3535
TELLMon protocol (UDP): 3545
TEX protocol: 3333
SIA IP (DC-09) protocol: 9999
Protocol: select the appropriate communication protocol for the given server or receiver from the
drop-down menu.
Available protocols:
TELLMon (custom TELL protocol for the TELLMon receiver and the MVP.next server);
TEX (custom TELL protocol for the TEX-MVP and the TEX BASE/PRO servers);
SIA IP (SIA DC-09).
Supervision message: enable/disable supervision message sending. Supervision message
sending cannot be disabled in case of using the TEX or the TELLMon communication protocol.
Supervision message interval: if supervision message sending is enabled, you can configure
the interval of message sending from 30 to 86400 seconds for the SIA IP protocol,
30 to 600 seconds for the TELLMon protocol, and 60 to 600 seconds for the TEX protocol.
Time zone: in this section you can select whether the given server or receiver sends the
timestamp used for synchronizing the system time in UTC or local time. It is important to select
the appropriate option for each server and receiver, since if the system time is set incorrectly,
events will be stored with the wrong timestamp.
Network protocol: according to the chosen communication protocol you can use TCP or UDP
network protocol. The UDP protocol allows for less data traffic. For the TEX communication
protocol only the TCP network protocol option is available.
AES key: the custom AES encryption key can be used for SIA IP protocol only. If an encryption
key is configured, the SIA IP packages will be encrypted with the given key, and they must be
decrypted on the receiver side using the same key. The maximum length of the AES key is up to
16 characters, or up to 32 characters in case of using hexadecimal format.
Send each message in a new session: if required for the given receiver, for the SIA IP protocol
it can be enabled to send each message in a new TCP session. In case of using UDP,
the device will open a new port for each message, if this option is enabled.
Backup reporting to CMS via SMS:
In case that the device fails to report the connected alarm system’s messages to the CMS servers
or receivers, as a backup solution, it is possible to forward the reports via SMS to a configurable
phone number. For this, it is necessary to enable the Backup reporting via SMSoption in the
notification template assigned to the affected events.