The device chooses in each case the added alarm system event filter which matches best the
event code received from the alarm control panel. For example if it finds two added alarm system
event filters at which the event type, the event code and the partition matches the event received
from the alarm control panel, but at one of them the zone section matches too, while at the other
one the zone section is filled in with "" characters, so the received event matches both alarm
system event filters, the device will choose the one at which the zone section matches too.
If an event code is received from the alarm control panel which does not match any of the event
filters configured, i.e., the device cannot find a reporting configuration for the given event code,
then it will report the given event to CMS automatically using the notification template named
DEFAULT” to ensure that all events are reported.
If you wish to report only specific events to CMS, add a filter that applies to all events, where
choose the “New event, Restore, Repeat” option for event type and fill the event code, partition,
and zone number fields with "" characters, and select for this the notification template named
EMPTY”. With this, reporting to CMS of any event received from the alarm control panel will be
disabled. Thereafter, configure and add the events you wish to be reported. In this case only the
specified events will be reported, and the device will send the kiss-off (ACK) signal to the alarm
control panel for all other events but will not report them to CMS.
The system supports adding up to 500 alarm system event filters.
Available options:
Reading the settings from the device:
To read the settings from the device, click on the Readbutton. This will read all
settings in all menus.
Writing the settings into the device:
After changing the settings or entering new settings, to take effect, it is necessary to
write the new settings into the device by clicking on the Writebutton. This will write
the changes only, but all changes made in any menu.
Adding new alarm system event:
To add a new alarm system event, click on the “New” button.
Creating a copy of an existing alarm system event:
To create a copy of the selected alarm system event, click on the Clonebutton.
Please note that the new copy should have a different unique name.
Editing alarm system event settings:
To edit the settings of the selected alarm system event, click on the “Edit” button.
Deleting an alarm system event:
To delete the selected alarm system event, click on the “Delete” button.
Please note that after you make changes, you must write the settings into the device
to be applied. For this, click on the “Write button.