Event:
Name: custom name of the event. The name entered in this section is used for identification of
the given event within the program and in the event logs. The name should not be longer than 20
characters, and the following characters cannot be used: ^ ~ < > = | $ % " '.
Type: the type of the event. You can choose from the following options: new event, restore, repeat,
new event + restore, new event + repeat, restore + repeat, new event + restore + repeat.
Remote monitoring:
In this section you can configure the Contact ID event code expected from the alarm control panel
and can assign one of the preconfigured notification templates to the given event.
Event code: in this section you can configure the 3-digit Contact ID event code, consisting of
characters 0..9,A,B,C,D,E,F, or "", which you wish to filter, from the messages coming from
the alarm control panel.
The software includes a built-in event code search tool which contains the list of standard
Contact ID codes. The search tool opens by clicking on the icon with the question mark symbol
placed in front of the event code input field.
In the event code search tool, you can search for events by name or by event code. For searching
by name, start typing the name of the searched event code in the field under the Event name
column header. For searching by event code, start typing the searched event code number in the
field under the Event code column header. The search tool will filter the list automatically
according to the hits. You can select an event code by clicking on it in the list, then the program
will paste this automatically into the event code input field after clicking on the “OK” button.
Partition: in this section you can configure the partition number consisting of characters 00…99,
or "", which you wish to filter from the messages coming from the alarm control panel.
Zone: in this section you can configure the zone number consisting of characters 000…999,
or "", which you wish to filter from the messages coming from the alarm control panel.
Notification template: in this section you can select a preconfigured notification template which
you want to use for the given event. If you want to use additional notification templates, these
should be added prior to configuring the events. If you do not want to send a report to CMS on the
given event, select the template named “EMPTY”.