EasyManua.ls Logo

tell Adapter2 - Page 75

tell Adapter2
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
Output:
In this section you can configure the output to be controlled upon receiving the configured alarm
system event.
Output control mode: in this section you can configure the control mode of the output.
Available options:
None: the output will not be used.
Monostable: the output will be activated for the time configured in the Duration section
of the output parameter settings, then it will revert to normal state automatically.
The duration can be configured from 5 milliseconds to 1 hour.
Bistable ON: the output will be activated permanently and will change state only upon
receiving a different command or upon power loss.
Bistable OFF: the output will become deactivated.
Pulse series: the output can be controlled by pulse series as well. The number of pulse
series can be configured from 1 up to 3. For each pulse it can be configured how long the
output should be activated, how long should be deactivated, the number of repetitions and
the pause between repetitions. The active periods can be configured from 5 milliseconds to
1 hour, the number of repetitions can be configured from 1 to 10, and the pause between
pulses can be configured from 5 milliseconds to 1 hour too.
Output parameter settings: this option becomes available if an output control mode is selected
which has further settings. In this section you can configure the additional settings of specific
output control modes, such as timings for monostable control and pulse series. Click on the Edit
button to open the parameter configuration window.
Voice call notification:
In this section you can configure phone calls to be made when the given alarm system event
occurs. The device will call the selected phone numbers and play the selected voice messages.
You can upload voice messages as audio files in the “Voice messages” menu.
Voice call: in this section you can select the user phone numbers to which calls should be made.
The phone numbers should be configured in advance in the Reporting channelsmenu. Calls
will be made to the numbers enabled with the help of the checkboxes in the drop-down list.
Voice message: in this section you can select the voice message which should be played in the
calls when the given event occurs. When receiving a call from the device, a built-in siren tone will
be played before each voice message. If a voice message has been configured for which no
message has been uploaded, the siren tone will be played continuously throughout the call.
Text-based notifications:
In this section you can configure text-based messages to be sent when the given alarm system
event occurs.
SMS notification: in this section you can select the user phone numbers to which SMS message
should be sent when the given event occurs. The phone numbers should be configured in advance
in the Reporting channelsmenu. The text message will be sent to the numbers enabled with
the help of the checkboxes in the drop-down list.
Push notification (Adapter2 PRO only): in this section you can select the mobile devices to which
Push notification should be sent when the given event occurs. The mobile devices should be
configured in advance in the Mobile devicesmenu. Push notification will be sent to the mobile
devices enabled with the help of the checkboxes in the drop-down list.

Table of Contents