E-mail notification (Adapter2 PRO only): in this section you can select the addressees to whom
e-mail should be sent when the given event occurs. The e-mail addresses should be configured
in advance in the “Reporting channels” menu. E-mail will be sent to the addressees enabled with
the help of the checkboxes in the drop-down list.
Message: in this field you can enter a custom message of maximum 45 characters, which you
wish to be sent to the selected phone numbers, mobile devices, or e-mail addresses when the
given event occurs. The device will send the same message for each notification channel (SMS,
Push, e-mail).
The device is capable to insert various dynamic data in the text of the message using variables.
The device will automatically replace the variable written in the message with the data related to
the given variable when it sends the message.
Available variables:
$cn: the event name configurable in the “Custom event code names” menu, associated with
the event code received from the alarm control panel. If you have not modified the new/restore
event name, the device will replace the variable with the default event name in the message.
$cp: the partition name configurable in the “Custom partition names” menu, associated with
the partition number received from the alarm control panel. If a custom partition name has not
been configured for the given partition number, the device will replace the variable with the
partition number in the message. (e.g.: 01).
$cz: the zone or user name configurable in the “Custom zone names” and “Custom user
names” menu, associated with the zone/user number received from the alarm control panel.
If a custom zone or user name has not been configured for the given zone/user number,
the device will replace the variable with the zone/user number in the message. (e.g.: 001).
$cid: the complete Contact ID message received from the alarm control panel
(eg.: 123418113001001).
$cc: the Contact ID event code received from the alarm control panel (e.g.:130).
$name: the name configured for the given event in the “Alarm system events” menu.
$in1…in4: the actual state of the given contact input (0=idle, 1=activated)
$rel1: the actual state of the relay output (0=idle, 1=activated)
$ps: the momentarily measured supply voltage value (e.g.: 13563 mV).
Camera (Adapter2 PRO only): in this section you can select the IP camera which you wish to
assign to the given event. IP cameras should be configured in advance in the “IP cameras” menu.
If you have configured a Push notification for the given event, the mobile application will
automatically offer to view the picture of the IP camera associated with the given event, when the
message is received. If you have configured an e-mail notification for the given event, the URL of
the IP camera assigned to the event will be sent along with the message in the given e-mail.
Click “OK” to accept the changes or “Cancel” to quit without saving.
Adding a new alarm system event filter:
• Click on the “New” button.
• Configure the event you wish to filter based on the above.
• Click on the “Write” button to write the changes into the device.