Table 15-9. Short Circuit in Discharge 1 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 0)
Setting
(1)
Time Setting Time Setting Time Setting Time
0x00 0 µs 0x04 244 µs 0x08 488 µs 0x0C 732 µs
0x01 61 µs 0x05 305 µs 0x09 549 µs 0x0D 793 µs
0x02 122 µs 0x06 366 µs 0x0A 610 µs 0x0E 854 µs
0x03 183 µs 0x07 427 µs 0x0B 671 µs 0x0F 915 µs
(1) The data flash setting Protection:AFE Thresholds:SCD1Threshold[7:4] sets the delay time.
Table 15-10. Short Circuit in Discharge 1 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 1)
Setting
(1)
Time Setting Time Setting Time Setting Time
0x00 0 µs 0x04 488 µs 0x08 976 µs 0x0C 1464 µs
0x01 122 µs 0x05 610 µs 0x09 1098 µs 0x0D 1586 µs
0x02 244 µs 0x06 732 µs 0x0A 1220 µs 0x0E 1708 µs
0x03 366 µs 0x07 854 µs 0x0B 1342 µs 0x0F 1830 µs
(1) The data flash setting Protection:AFE Thresholds:SCD1 Threshold[7:4] sets the delay time.
Table 15-11. Short Circuit in Discharge 2 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 0)
Setting
(1)
Time Setting Time Setting Time Setting Time
0x00 0 µs 0x04 122 µs 0x08 244 µs 0x0C 366 µs
0x01 31 µs 0x05 153 µs 0x09 275 µs 0x0D 396 µs
0x02 61 µs 0x06 183 µs 0x0A 305 µs 0x0E 427 µs
0x03 92 µs 0x07 214 µs 0x0B 335 µs 0x0F 458 µs
(1) The data flash setting Protection:AFE Thresholds:SCD2 Threshold[7:4] sets the delay time.
Table 15-12. Short Circuit in Discharge 2 Delay
(Settings:AFE:AFE Protection Control [SCDDx2] = 1)
Setting
(1)
Time Setting Time Setting Time Setting Time
0x00 0 µs 0x04 244 µs 0x08 488 µs 0x0C 732 µs
0x01 62 µs 0x05 306 µs 0x09 550 µs 0x0D 792 µs
0x02 122 µs 0x06 366 µs 0x0A 610 µs 0x0E 854 µs
0x03 184 µs 0x07 428 µs 0x0B 670 µs 0x0F 916 µs
(1) The data flash setting Protection:AFE Thresholds:SCD2 Threshold[7:4] sets the delay time.
www.ti.com AFE Threshold and Delay Settings
SLUUCO0 – APRIL 2022
Submit Document Feedback
BQ28Z610-R2 131
Copyright © 2022 Texas Instruments Incorporated