3-1
3 STANDARD MEASUREMENT MODE
3STANDARD MEASUREMENT MODE
3.1 Angle Measurement
3.1.1 Measuring Horizontal Angle Right and Vertical Angle
Make sure the mode is in Angle measurement.
Operating procedure Operation Display
1 Collimate the 1st target (A).
Collimate
A
2 Set horizontal angle of target A at 0 00' 00".
Press [F4](0 set)key and [F6](SET) key.
[F4]
[F6]
3 Collimate the 2nd target (B).
The required H/V angle to target B will be
displayed.
Collimate
B
Reference : How to Collimate
1 Point the telescope toward the light. Turn the diopter ring and adjust the diopter so that the cross
hairs are clearly observed.
(Turn the diopter ring toward you rst and then backward to focus.)
2 Aim the target at the peak of the triangle mark of the sighting collimator. Allow a certain space
between the sighting collimator and yourself for collimating.
3 Focus the target with the focusing knob.
*If parallax is created between the cross
hairs and the target when viewing
vertically or horizontally while looking
into the telescope, focusing is incorrect
or
diopter adjustment is poor. This
adversely
affects precision in measurement or
survey
Eliminate the parallax by carefully
focusing
and using diopter adjustment.
Prog
Std
Mem
Com
Adj
Para
2001-07-10 15:30:40
STANDARD MEASUREMENT MODE
Angle measurement, Distance measurement,
Coordinate measurement .
[Press [F2] key.]
V : 87°55'45"
HR: 180°44'12"
SD HD NEZ 0SET HOLD P1
H-0SET
HR: 00°00'00"
ESC SET
V : 87°55'45"
HR: 00°00'00"
SD HD NEZ 0SET HOLD P1
V : 87°55'45
HR: 123°45'50
SD HD NEZ 0SET HOLD P1
Focusing knob
Telescope eyepiece (Diopter ring)