7-2
7 PARAMETERS SETTING MODE
8.Dist. Unit meter/feet
Select the distance measuring unit Meter or Feet shown on
the display.
9.C.F. m/ft Us.f /Intl.f
Select the meter / feet conversion factor.
US survey feet
1m=3.280833333333333 ft.
International feet
1m=3.280839895013123 ft.
10.Min. Dist. OFF / ON
Select OFF or ON for the minimum distance in ne mode.
OFF:1mm :ON: 0.2mm
11.S/A buzz. OFF / ON Select the Audio tone OFF or ON for the Set Audio Mode.
12.W-corr. OFF/ 0.14 / 0.20
Select the coefcient correction for refraction and earth
curvature. Selections for the refraction coefcient are; OFF
(No correction), K=0.14 or K=0.20.
13.N/E/Z mem OFF / MEM.ON
Select the option to store the coordinates (NEZ) for the
occupied point when power is turned off..
14.N/E- ord. NEZ / ENZ
Select the display format in the coordinate measurement
mode for NEZ or ENZ.
15.Temp. Unit °C / °F Select the temperature unit for the atmospheric correction.
16.Pres. Unit mmHg/inHg/hPa Select the air pressure unit for the atmospheric correction .
17.R/L Lock OFF / ON
Prohibit switching angle right or left by soft key in angle
measurement mode
OFF : Switching is possibleON : Prohibition
18.m/ft Lock OFF / ON
Prohibit switching meter unit or feet unit.
OFF : Switching is possible ON : Prohibition
19.Date m/d/y d/m/y y/m/d
Select the date format shown on the display.
(Month/Date/ Year), (Date/ Month/ Year) or (Year / Month /
Date)
20.A. P. OFF OFF / ON (01 to 99)
The auto power off function can be turned OFF or set ON.
OFF : not use ON :1 to 99 minutes (numeric key)
21.Heater OFF / ON
The heater option for both display units can be turned OFF or
ON.
22.EDM wait OFF / ON (01 to 99)
EDM cut off time after distance measurement is completed
can be changed.
OFF : EDM is cut off immediately after measuring
ON : EDM is cut off after 1 to 99 minutes.
23.L.P.OFF
manual /
auto 01 to 99
Laser Plummet function can be turned OFF automatically.
manual ON/OFF by pressing soft key.
auto 01~99 : Laser Plummet function is cut off after 1~99
minutes.