Specifications
HiPer+ Operator’s Manual
C-2
Survey Accuracy
Static, Fast Static For L1+L2 – H: 3mm + 0.5ppm (x baseline length);
V: 5mm + 0.5ppm (x baseline length)
For L1 – H: 5mm + 1.4ppm (x baseline length);
V: 7mm + 1.9ppm (x baseline length)
Kinematic, RTK
For L1+ L2 – H: 10mm + 1.0ppm (x baseline length);
V: 15mm + 1.0ppm (x baseline length)
For L1 – H: 15mm + 2.0ppm (x baseline length);
V: 20mm + 2.5ppm (x baseline length)
Cold Start
Warm Start
Reacquisition
< 60 sec
< 10 sec
< 1 sec
Technology
Co-Op tracking
Low signal tracking
Advanced Multipath mitigation
WA A S
Adjustable PLL and DLL parameters
Radio Modem
UHF Radio modem Internal Rx or External Tx/Rx
GSM modem Europe and Asia – 900/1800 MHz
USA and Canada – 900/1900 MHz
Bluetooth Module specifications
Range up to 10 m (indoor); up to 50 m (outdoor)
Supported profiles Serial port profile
Frequency Country
Code
North America and Europe
Data Storage and Display
Status Indicators Four, three-color LED’s
Table C-1. HiPer+ Specifications (Continued)
Component Details

Table of Contents