Charging the Internal Batteries
P/N 7010-0526
2-7
Charging the Internal Batteries
Before beginning to work, fully charge the internal batteries for
maximum operating time (Figure 2-5 on page 2-8).
With a full charge, the internal batteries should power the GPS
receiver, the Bluetooth module (optional), and the PDL radio modem
for at least 15 working hours. If the internal radio modem is turned
off, the HiPer+ should run at least 18 hours with fully charged on-
board batteries.
1. Connect the power cable to the power supply unit.
2. Connect the SAE connectors on the power adapter cable and
power supply unit.
3. Connect the power adapter cable to power port on the receiver.
4. Plug the power supply into an available outlet. Leave for
approximately 2.5 hours to fully charge the batteries.
5. Press the Reset key on the receiver to ensure it is in Normal mode
for charging. The receiver will not charge in Zero Power mode.
6. Leave overnight.
A nine-hour charge will charge the batteries about 90%. A ten-
hour charge will fully charge the receiver. The internal batteries
cannot be overcharged.
NOTE
The batteries are shipped from the factory without
power. Fully charge the batteries before surveying.
CAUTION
Use a grounded wall outlet or grounded surge
protector while charging.