Specifications
HiPer+ Operator’s Manual
C-4
Logging Interval 0.05 to 86400 seconds, depending on purchased options
Power
Internal battery Li-ion, 4000 mAh, 7.4 V
Battery size 132 x 35 x 18 (mm)
Battery weight 165 g (1 battery)
Number of built-in
batteries
2 batteries
Change battery non-detachable battery
Operating time ~15 hours with UHF PDL Radio ON
~18 hours with UHF PDL Radio OFF
External power 1 port
Input voltage 6 to 28 V DC (for work)
9 to 28 V DC (for charge battery)
Maximum Charge Current <=2 Amp
Consumption Typical: 2.5W
Maximum: 2.7W
On-board Backup battery for timekeeping and almanac data
storage
10 years minimum operation
Environment
Operating
temperature
-30 C° to + 60 C° with batteries
Storage temperature -40 C° to +75 C° with batteries
Physical
Enclosure Aluminum extrusion, rainproof
Color Topcon Yellow
Dimensions W:158.5 x H:113 x D:173 mm
Table C-1. HiPer+ Specifications (Continued)