Calibration
MachineCalibration
28
X‐63/X‐63i/X‐62/X‐33/X‐32InstallationandCalibrationManual P/N:7010‐0697
8. Oncetheboompitchvalueissettozero,tapSetnexttoRoll,settheboomrollvaluetomatch
thebodyrollvalue,andtapSetagain(Figure32).
Figure32:SetBoomRollValuetoMatchBodyRollValue
9. TapOKtocontinue.
Secondary Boom Sensor Calibration (Optional)
Liketheprimaryboomsensor,thesecondaryboomsensorcalibrationrequiresboththepitchandtheroll
calibration.Thesamemethodusedforcalibratingtheprimaryboomsensorisusedtocalibratethe
secondaryboomsensor.
Makesuretocheckthe
SecondaryBoom
checkbox(Figure33).
See“BoomSensorCalibration”on
page27fordetailsoncalibratingthesecondaryboomsensor.
Figure33:SecondaryBoomCheckBox
IfthebodyPitchandRollhasnotchangedfromwhenthebodysensorwascalibrated,enterthe
recordedbodyRollvaluefortheboomRollvalue.IfthebodyPitchandRollhaschanged,
navigatetothebodysensorandrecordthenewbodyRollvalue,andenterthatnewvaluefor
theboomRollvalue.