EasyManua.ls Logo

Toptech Systems MultiLoad II SCS

Default Icon
515 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Weights & Measures
287
Firmware Version 3/4.31.37
Table
Description
Table PTB-BIO
This API BIO tables are used for Methode3 from the PTB Community. Select PTB-BIO table
combined with API BIO to choose the wanted product.
Formula: V(T) = V0 *{1 + [A1 *(T T0) + A2 *(T T0)2 + A3 *(T T0)3]}
V0 = Volume @ base temperature
V(T) = Volume @ observed temperature
T0 = Base Temperature (15° C)
T = Observed Temperature
A1, A2, A3 = Biofuel coefficients
Product Type
A1
A2
A3
Ref. Density
E5
-1.2422 x 10-3
-9.1811 x 10-7
-5.3906 x 10-9
738.858
E10
-1.2415 x 10-3
-9.8712 x 10-7
-6.6333 x 10-9
741.447
E80
-1.1129 x 10-3
-6.5049 x 10-7
-8.8556 x 10-9
781.410
E85
-1.1023 x 10-3
-6.0110 x 10-7
-8.7249 x 10-9
784.549
E100
-1.0720 x 10-3
-4.5474 x 10-7
-8.3383 x 10-9
793.949
Benzin/Petrol
-1.2361 x 10-3
-6.7788 x 10-7
-3.8516 x 10-9
733.919
Diesel
-8.2239 x 10-4
5.1745 x 10-8
-1.3703 x 10-9
844.615
B5 RME
-8.2261 x 10-4
5.5270 x 10-8
-1.3289 x 10-9
846.439
B7 RME
-8.2258 x 10-4
5.4729 x 10-8
-1.3921 x 10-9
847.171
B100 RME
-8.2330 x 10-4
1.4698 x 10-7
-1.6545 x 10-9
883.314
B5 SME
-8.1922 x 10-4
2.9212 x 10-8
-1.0385 x 10-9
846.486
B7 SME
-8.1925 x 10-4
3.1305 x 10-8
-1.0918 x 10-9
847.253
B100 SME
-8.2132 x 10-4
1.0329 x 10-7
-1.0793 x 10-9
885.229
RME: Rapeseed oil methyl ester
SME: Soy bean oil methyl ester
TABLE ETH
BRAZIL
This table provides CTL factors for correcting volumes of ethanol at observed temperatures
to the volume at 20 C . Use this table if the following conditions exist:
The liquid is alcohol
Alcohol Percentage is known
Current Temperature is available.
Test temperatures can be entered on this screen that will calculate a CTL based on the test
temperature and the alcohol percentage. The test temperature and Calculated CTL are for
informational purposes and will not be used in calculations during operations.
Corrected density at 20 degrees will be calculated and stored.

Table of Contents