EasyManua.ls Logo

Toptech Systems MultiLoad II SCS

Default Icon
515 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Weights & Measures
317
Firmware Version 3/4.31.37
2. If the observed temperature is different from the unadjusted temperature displayed, there are two options:
- Press 1 and key in the observed offset (that is, the difference between the Temp Unadjusted and Temp
Adjusted).
- Or, press 2 and key in the observed temperature in the Temp Adjusted field, in which case the Temp
Offset will automatically be calculated and displayed.
Use the +/- key to toggle between a minus () sign and a plus (+) sign on the offset.
The temperature offset cannot exceed + or 3 degrees. If you enter a value greater than 3 in this field, the
value will change to 3, and the temperature will be adjusted by no more than + or 3 degrees. Likewise, if you
enter an observed temperature that exceeds the Temp Unadjusted value by 3 degrees, the offset will only
change by 3 degrees.
PRE #1 MTR #1 TEMPERATURE
Temperature Unadjusted: +42.27C
[1]Temperature Offset: +0.00C
[2]Temperature Adjusted: +42.27C
Status Ok
Next Prev Exit
PRE #1 MTR #1 TEMPERATURE
Temperature Unadjusted: +42.27C
[1]Temperature Offset: + C
[2]Temperature Adjusted: +42.27C
Status Ok
+/- Enter Exit

Table of Contents

Related product manuals