Chapter 16 – Firmware Revision History
436
Firmware Version 3/4.31.37
Corrected design in transaction archive that omitted storing the year in the
date.
Removed unused datestr and timestr from RCU Setup Database.
Removed unused Report Time, Detailed Report, and Auto Report from RCU Setup
Parameters.
Marked the Preset Select Timeout RCU Setup Parameter as NA on SMP builds.
Fixed bug where all RCU level NA parameters were logged as being reset to
defaults on every startup.
Added debug precompiler directive label LOG_TERMINAL_CLEAN to assist with
capturing screen shots for manuals.
Corrected bug that prevented the polling of the program and W&M switch when
system marked as not configured.
Corrected bug that caused corruption of preset batch temp/pressure/density
values.
Updated firmware version to 3.27.06.
Updated database version to 3.27.06 for RCU Setup Database.
03/27/07 3.27.07 WJP (released to Pemex)
Bug in 3.27.00-3.27.06 firmware checked Version instead of Product ID on firmware
uploads. Added dummy version strings to firmware image to allow uploading by
3.27.00-2.27.06 firmware.
Updated firmware version to 3.27.07.
04/05/07 3.27.08 WJP (released)
Fixed bug in custom logic port selection screen where "Select..." was displayed
instead of "Port #x" in picklist.
Updated firmware version to 3.27.08.
06/27/07 3.28.01 WJP (released to QA)
Per Measurement Canada changed Side Stream Blending Logic as:
Back calculation of main product stream component temperature is no longer
done.
Blend meter temperature/pressure/density is passed back to the main product
stream component level.
Blend meter temperature/pressure/density is passed up to preset level and side
stream temperature/pressure/density is not passed up to preset level.
Blend meter volume is passed up to preset level and side stream volume is not
passed up to the preset level.
API table listed for the main product stream is applied to the gross blend
meter volume and is passed up to the preset level.
CR - Offloading Air Eliminator High Flow Control functionality. Added two new
parameters "Alt. High Flow Rate" and "Alt. H.F. Rate FCM#" to change to an
alternate high flow rate when a status input changes. This change is intended for
single product delivery without blending.
Updated real time database version to 3.28.01.
Updated firmware version to 3.28.01.
07/18/07 3.28.02 WJP (released to Measurement Canada)
(Req. of Measurement Canada) Updated Ticket to include an "*" by any values not
measured for trade.
Updated default standalone ticket definitions to properly format ticket with
"*"s.
Added preset and component status bit to indicate when "gross value measured for
trade".
For Preset, when "gross value measured for trade" is not set, Temperature,
Pressure, Density, and Gross Volume may not be used for trade. Net Volume may only
be used for trade when MultiLoad is applying an API table to convert gross to net
for all components.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals