EasyManuals Logo

Toptech Systems MultiLoad II SCS User Manual

Default Icon
515 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #438 background imageLoading...
Page #438 background image
Chapter 16 Firmware Revision History
438
Firmware Version 3/4.31.37
Number of Components parameter added back into SMP builds.
ECO2008-001
Moved all flow rate parameters out of W&M control, except meter min and max
flow rates. TMS can change these values when a batch is not authorized.
Preset - Low Flow Rate
Preset - High Flow Rate
Preset - Alt. High Flow Rate
Component - High Flow Rate
Component - 1st Stage Trip Vol
Component - 1st Stage Flow Rate
Component - 2nd Stage Trip Vol
Component - 2nd Stage Flow Rate
ECO2008-002
Added ability to lock down additive calibration data and recipe percentage
under W&M protection. New parameters added.
Additive - W&M Recipe Percentage
Additive - W&M Additive Vol/Inject
Additive - W&M Vol/Inject Cal Factr
Additive - W&M Additive Mtr K-Factr
Additive - W&M Additive Mtr Factor
ECO2008-003
Added the ability to connect an Alibi Log to a Serial Port.
Added a communication port type of Alibi Log.
RTS and DTS are always driven active.
Data will only be transmitted when DCD, DSR and CTS signals are active.
If DCD, DSR or CTS remain inactive for 5 seconds or more, a printer alarm
will be raised.
Printer must be in hardware handshake mode, DTR used for pacing.
Also added printer flow control and alarming to ticket printing.
ECO2008-004
Added interface to allow TMS to display other preset volumes, separate from ML
values on the load screen.
Values will be maintained in a different color to clearly establish them as
not legally relevant and should not be used for trade.
Added new bay parameter "Number External Presets" to specify how many
external presets should be displayed.
All external presets are displayed in a different color with a message
indicating "Not Legal for Trade".
Added R/U401 register to update displayed external preset data.
When an external preset is selected, the MultiLoad state will go to an 'a'-
'h' matching the preset number.
MAMppp - can be sent by the host to return to the load screen when done
driving the screen.
ECO2008-007
Added ability to reprint any ticket or range of tickets from the transaction
archive.
A serial port must be configured as connected to a printer.
When viewing the header of a transaction in Views and Inquiries -> Transactions
a footer prompt of "1=Print Transaction" now appears instructing how to print the
transaction.
After viewing two different transactions, a footer prompt of "2=Print
Transactions xxxx-yyyy" now appears instructing how to print the selected range of
transactions.
Transactions that have been printed before will be marked as Duplicates on the
ticket. (W&M requirement)
Note: Per ECO2008-003, hardware handshake and alarming has also been added.
(W&M requirement). This will require that customers properly wire the DTR and

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals