Chapter 16 – Firmware Revision History
454
Firmware Version 3/4.31.37
Added new Meter configuration parameters to support live Relative Density input:
"Relative Density Sensor Enabled"
"Relative Density Sensor FCM#"
"Default Relative Density"
"Alarm Low Relative Density"
"Alarm High Relative Density"
"Relative Density Alarm Time"
"Relative Density at 4mA"
"Relative Density at 20mA"
"Relative Density Offset"
Added new Component configuration parameter, "Default Relative Density".
Relative Density weighting calculations are the same as Density Calculations.
Added ability for API functions to use live Relative Density.
Added ability to read component current relative density in MRS command.
Added ability to read component meter current relative density in MRS command.
Updated preset and component status screens to display relative density.
Added ability to read component current relative density from Modbus register
6292 ... 6483.
View Relative Density Screen (modify offset) added to Views and Inquiries.
Updated API table setup screen to handle test Relative Densities.
Corrected bug where if entry into program mode followed PIN input, caused "***"
to appear when entering numbers in program mode.
Updated view transaction to display density instead of pressure.
Updated view transaction to display totalizers stored in transactions.
Updated view transaction to display no net, temperature or density for additives.
Removed dates and line number from message log display to increase the display
from 57 to 71 characters.
Added ability to include ending totalizers in a transaction.
Added new configuration format type TOTALIZER_SELECTION=25. (MultiMate update
needed)
Added new RCU configuration parameter, "Print Totalizers" to select what
totalizers (PMCA) should be included in a transaction and alibi log.
Increased the max number of Transaction Details from 99 to 999.
Added optional extension to R800 register to support reading details over 99.
Added blank line between each preset totalizer groups printed on ticket.
Added new Preset configuration parameter, "Default Preset" to automatically enter
a preset quantity.
Updated preset prompt routine to skip preset if default preset is specified.
Added new Meter configuration parameter, "Meter Address" to specify the Modbus
address of a serially connected mass meter.
Added new W&M Component configuration parameter, "API Extrapolated Range" to
allow the use of API tables in the extrapolated ranges.
Updated proving mode to always use proving low flow rate and proving low flow
volume.
Corrected bug in Preset Net Totalizer not correctly showing preset net volume
with side stream. Component 1 Net was also impacted, but transaction volumes were
not affected.
For meter creep on an unauthorized batch, preset product code is now "CREEP "
instead of "000000" (first product). Product description on ticket displayed at
"Meter Creep".
Updated ticket printing routine to print product code from transaction and not
the currently loaded product list.
Updated set clock routines and serial interface to return an error when values
are out of range.
Increased range of low flow alarm time from 65.535 seconds to 999.999 seconds.
Added new Preset configuration parameter, "Auto Batch Authorize" to support auto
batch authorizations when product and volume are already specified and program key
off in standalone mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals