Multi Pro 1200/1250 Page 6 -- 51 Spray System
Disassembly (Fig. 55)
IMPORTANT: Make sure to remove and neutralize
chemicals from tank and spray components before
disassembly.Wearprotectiveclothing,chemicalre-
sistant gloves and eye protection during repair.
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
2. Drain spray tank (see Operators Manual and Fig.
56).
3. Label hoses to allow proper installation after repairs
arecompleted.Loosenhoseclampsandremovehoses
from hosebarbs that are to be disassembled.
4. Disassemble drain assembly using Figure 55 as a
guide. Discard all removed O--rings and gaskets.
Assembly (Fig. 55)
NOTE: CoatallO--ringswithvegetableoilbeforeinstal-
lationtoreducethechanceofdamageduringassembly.
1. Assemble drain assembly using Figure 55 as a
guide. Replace all removed O--rings and gaskets.
2. Using labels placed during disassembly, install
hoses to hosebarbs and secure with hose clamps.
3. Make sure that drain valve is closed and secured to
sprayer with lynch pin.
4. Check spray tank for leaks. Repair all leaks before
returning the sprayer to service.
1. Drain valve (closed)
2. Lynch pin
3. Drain valve (open)
Figure 56
2
1
3
2
2
1
Spray
System