Multi Pro 1200/1250
Page 5 -- 20
Electrical System
Master Boom (Foot) Switch (Multi Pro 1250 only)
The master boom switch on Multi Pro 1250 sprayers is
located on the floorboard of the machine (Fig. 32).
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Locate switch and unplug wire harness connector
from switch.
3. The switch terminals are shown in Figure 33. Conti-
nuity should exist between the common terminal and
only one of the side terminals. When the switch is de-
pressed, continuity should exist between the common
terminal and the other side terminal. Regardless of
switch position, there should never be continuity be-
tween the two side terminals.
4. Connectthewireharnessconnectortotheswitchaf-
ter testing.
1. Operator floorboard 2. Master boom switch
Figure 32
2
1
1. Common terminal 2. Side terminal
Figure 33
2
1
2