Multi Pro 1200/1250
Page 5 -- 11
Electrical System
Hour Meter
Thehourmeter is located onthecontrol console nextto
the operator seat.
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Remove console panel. Disconnect the harness
electrical connectors from the terminals on the hour
meter.
3. Connectthepositive(+)terminalofa12VDCsource
to the positive (+) terminal of the hour meter.
4. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
5. The hour meter should move a 1/10 ofan hour in six
(6) minutes.
6. Disconnect voltage source from the hour meter.
7. Connect yellow/red harness wire to the positive (+)
terminalof thehourmeter andblack harness wireto the
other meter terminal. Install console panel.
Figure 12
Headlight Switch
The headlight switch is located on the control console
next to the operator seat (Fig. 13).
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Remove console panel, locate headlight switch and
unplug wire harness connector from switch.
3. The switchterminalsaremarkedas showninFigure
14. In the ON position, continuity should exist between
the two terminals. In the OFF position, there should be
no continuity between the switch terminals.
4. After testing, connect the harness connector to the
switch. Install console panel to machine.
1. Control console 2. Headlight switch
Figure 13
2
1
Figure 14
BACK OF SWITCH
Electrical
System