Multi Pro 1200/1250
Page 5 -- 10
Electrical System
Neutral Switch
Theneutralswitchisattachedtothes hiftleverassembly
(Fig.11).Theswitchisanormallyopen proximityswitch
that is closed when the shift lever is in the neutral posi-
tion. The neutral switch allows engine cranking/starting
only when the machine is in neutral.
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Locate neutral switch on the shift lever assembly. If
needed, remove air cleaner cover to ease access to
switch.Disconnectthewireharness connectorfromthe
switch.
3. Check the continuity of the switch by connecting a
multimeter (ohms setting) across the connector termi-
nals.
4. Withtheshiftleverintheneutralposition,theneutral
switch should be closed (continuity).
5. Depress the brake pedal to allow the shift lever to
move. While watching the multimeter, move the shiftle-
ver out of the neutral position. Continuity of the neutral
switch should be broken as the lever is moved and the
interlock switch opens.
6. If necessary, replace switch.
7. Connect the wire harness c onnector to the switch.
8. If removed, install air cleaner cover.
1. Shift lever
2. Sensing tab
3. Shifter bracket
4. Neutral switch
Figure 11
1
2
3
4