Multi Pro 1200/1250
Page 5 -- 21
Electrical System
Spray Valve Switch (Multi Pro 1250 only)
Thethree(3)sprayvalveswitchesfortheMultiPro1250
sprayers are located on the spray control console (Fig.
34). The switches are identical.
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Locate spray valve switch, remove console panel
and unplug machine wire harness connector from
switch.
3. The switchterminalsaremarkedas showninFigure
35. In the ON position, continuity should exist between
terminals 2 and 3 and also between terminals 5 and 6.
IntheOFFposition,continuityshouldexistbetweenter-
minals 1 and 2 and also between terminals 4 and 5.
4. Terminals 7 (--) and 8 (+) are used for the indicator
light in the switch. The light should be illuminated when
the switch is in the ON position.
5. Connect the harness connector to the switch after
testing. Install console panel to machine.
1. Spray control console
2. LH spray valve switch
3. Center valve switch
4. RH spray valve switch
Figure 34
1
2
4
3
Figure 35
46
1
5
82
7
3
BACK OF SWITCH