Multi Pro 1200/1250
Page 5 -- 25
Electrical System
Battery Storage
If the machine will be stored for more than 30 days:
1. Remove the battery and charge it fully (see Battery
Service in this section).
2. Either store battery on a shelf or on the machine.
3. Leavecablesdisconnectedifthebatteryisstoredon
the machine.
4. Storebatteryinacoolatmospheretoavoidquickde-
terioration of the battery charge.
5. Tohelp preventthebatteryfromfreezing,makesure
it is fully charged (see Battery Service in this section).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
thanifthemachineisstoredin alocationwheretemper-
atures are cool.
Wear safety goggles and rubber gloves when
workingwithelectrolyte.Charge batteryinawell
ventilatedplace so gases produced while charg-
ing can dissipate. Since these gases are explo-
sive, keep open flames and electrical sparks
away from the battery; do not smoke. Nausea
may result if the gases are inhaled. Unplugchar-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
WARNING
IMPORTANT: Do not remove battery fill caps while
cleaning.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
casecleanbecauseadirtybatterywilldischargeslowly.
A. Clean batteryby washingentirecasewith asolu-
tionofbakings odaandwater.Rinsewithc learwater.
B. Coat battery posts and cable connectors with
Battery Terminal Protector (see Special Tools in this
chapter) to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
WARNING
Connecting battery cables to the wrong battery
postcould resultin personalinjury and/ordam-
age to the electrical system.
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Connect cables with
positive(+)cablefirst.Coatbatterypostsandcablecon-
nectors with Battery Terminal Protector (see Special
Tools in this chapter) to prevent corrosion.
5. Checkelectrolytelevelevery25operatinghoursand
every 30 days if machine is in storage.
6. Maintain celllevelwithdistilledwater.Do notfillcells
above the fill line.
Electrical