Multi Pro 1200/1250Page 3 -- 4Kohler Gasoline Engine
Adjust Choke Cable
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from the ignition
switch.
2. Remove air cleaner cover and air filter from engine
(see Operator’ s Manual).
3. Move choke control on control panel while watching
choke plate in carburetor.
A. Choke plate should be fully open when choke
control is pushed in.
B. Choke plate should be fully closed when choke
control is pulled out.
4. If cableadjustmentisneeded, loosencap screwand
nut that secure choke cable clamp. Reposition cable to
allow correct choke operation. Secure choke cable
clamp.
5. Reassemble air cleaner.
Figure 3
1. Choke cable
2. Cable clamp
3. Choke lever
2
1
3