110
9.8 RAM CLEAR
Contents of RAM CLEAR menu
9.8.1 NO RAM CLEAR
This option is provided for users who access this menu by mistake, and intended to exit from the RAM clear
menu without performing any RAM clear.
9.8.2 MAINTE.CNT CLEAR
The following maintenance counter data is cleared.
・ ALL COUNTER
FEED
PRINT
CUT
OTHER
Notes: 1. Maintenance counter data to be cleared and the initial values after maintenance counter clear
Parameter and cleared items
Ribbon motor drive time
Head-up solenoid driver time
RS-232C hardware error count
Momentary power interruption count
<Reference: Maintenance counter printout>
<< COUNTER >>
TOTAL FEED 4.8km [QM]
FEED 0.0km ··· Label distance covered
FEED1 4.8km
FEED2 0.0km
FEED3 0.0km
FEED4 0.0km
PRINT 0.0km ··· ②Print distance
PRINT1 4.5km
PRINT2 0.0km
PRINT3 0.0km
PRINT4 0.0km
CUT 0 ········· ③Cut count
HEAD U/D 0 ········· ④Head up/down count
RIBBON 0h ······· ⑤Ribbon motor drive time
SOLENOID 0h ······· ⑥Head-up solenoid driver time
232C ERR 0 ········· ⑦RS-232C hardware error count
SYSTEM ERR 0 ········· ⑧System error count
POWER FAIL 0 ········· ⑨Momentary power interruption count