96
9.5.28 RIBBON TORQUE
Normal
Low
Reserved1 (only B-EX6T1/T3)
9.5.29 FRONT RIBBON MOTOR
The menu structure of FRONT RIBBON MOTOR menu
Menu item
<2>SET PARAMETERS
FRONT RIBBON MOTOR
Normal Torque
Low Torque
Reserved1 (only B-EX6T1/T3)
9.5.29.1 Normal Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The fine adjustment value for the ribbon take-up motor is limited depending on the print speed.
Print speed
5 ips or slower
8 ips or slower
10 ips or faster
Fine adjustment value
+10 to +6
+5 to +1
-0 to -15
3. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.
9.5.29.2 Low Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The fine adjustment value for the ribbon take-up motor is limited depending on the print speed.
Print speed
5 ips or slower
8 ips or slower
10 ips or faster
Fine adjustment value
+10 to +6
+5 to +1
0 to -15
3. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.
9.5.29.3 Reserved1 (only B-EX6T1/T3)
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step