EasyManua.ls Logo

Toshiba Qosmio G30 - Page 459

Toshiba Qosmio G30
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix J Maintenance of TOSHIBA RAID Appendices
QOSMIO G30 Maintenance Manual (960-546) [CONFIDENTIAL] J-27
[View Drive Log] menu is as follows
Table J-10 Content of View Drive Log menu
Option Explanation
Change Port Changes the display of the own log and redundant log. At the
beginning, the Port-0’s own log and the redundant log are displayed.
Go to Event When this option selected, it moves to the log with designated
number.
The key function in [View Drive Log] key is as follows.
Table J-11 Function of key in View Drive Log
Key Function
[PageUp] Scrolls upward step one by one.
[PageDown] Scrolls downward step one by one.
[Home] Jumps to the oldest log in the latest 7,168 logs.
[End] Jumps to the latest log.
[Ctrl][Home]
Jumps to the oldest log that is older than 7,168 logs and the
identification ID is recorded.
[Tab] Switches [OWN] window and [REDUNDANT] window.
Force OFFLINE
Selecting this option in [Physical Drive] menu of Setup Utility can set the physical
drive to offline by force. Follow the procedure below.
1. Select [Physical Drive] in [Main Menu].
2. Select [Force OFFLINE] in [Physical Drive].
3. Select the drive that you want to set it to offline with [Space] key in [Physical
Drive] and press [Enter] key.
4. Selecting “OK” in [Confirmation] stores the setting.
Scan
When [Scan] in [Physical Drive] menu is selected, it scans physical drive. This is used
to recognize the drive after replacing failed drive.

Table of Contents

Other manuals for Toshiba Qosmio G30

Related product manuals