Voice Mail Configuration
Parameters
3-34 Strata CIX Voice Mail Programming 01/07
sys_connect_tone Determines whether voice mail beeps when completing a transfer.
Possible values:
True: Voice mail plays a beep when completing a transfer.
False: (default) Voice mail does not play a beep when completing a
transfer.
sys_default_user_agent User Agent used by the main application at startup.
Default: 990
sys_directory_min_digits Specifies the number of digits the caller has to enter before the directory
lookup application starts searching the directory.
Default: 3
sys_discard_SMDI_source Discards SMDI information for calling party ID when a message is sent from
998 or a Direct Send User Agent.
Possible values: True, False (default)
sys_dtmf_gate Before dialing any User ID extension, voice mail verifies that DTMF was
entered since the call last accessed the User ID (default is 991) specified in
the DONE chain of the initial User ID (default is 990).
This “gate” prevents the transfer of a dead/phantom call to the Operator on
those switches that do not have disconnect supervision. Voice mail does not
perform the “gate” action when the Extension field begins with the “@”
character.
Possible values:
True: (default) When prompted, the Caller must say “yes” to complete the
chain and transfer.
False: Caller does not have to say “yes” to complete the chain and
transfer.
sys_dtmf_interdigit_delay Time between digits in DTMF dialing in ms. units.
Default: 50
sys_fax_dl_init A token %A is replaced by this parameter, usually it is a dial code to access
an outside line.
Note This parameter is not currently supported.
Default: 9 (dial 9 and pause for two seconds)
sys_fax_fail_entry Specifies whether voice mail resends a fax if it detects a failure during
transmit.
Note This parameter is not currently supported.
Possible values:
0 no resent
1 resends starting from the first page
2 resends starting from the failure page
Default: 0