MAINTENANCE MANUAL
2.2.4 Check of Each Axis for Operation
Turn on the main power switch of the controller, then keep the EMERGENCY
pushbutton switch in the depressed condition. Move each axis by hand and make
sure that it can move smoothly.
For the axes 3 and 4, when the brake OFF pushbutton switch is pressed, the brake
is released. Take careful precautions at this time as the tool shaft may drop
according to the weight of the hand and tool.