3)  When adjustment of the tension is required, loosen the flange head bolts (M5 × 
16) securing the axis 3 and axis 4 motor bases, respectively.    Measure the 
tension on the tension meter while adjusting the tension adjustment bolt (axis 3: 
M4 × 35, axis 4: M5 × 30). 
  4)  When the tension has fallen under the appropriate range, tighten the flange 
head bolts. 
  5)  Mount the arm 2 cover.    Now the adjustment completes. 
STE 85306 